C-2

Fusion Approach
Key Technologies
Experimental Results
PublicationDensity (m-3)Temperature (keV)Energy Confinement Time (s)Triple Product (m-3 keV s)
A new high performance fi...
 4×1019(electron)0.2(electron) 0.5(ion)
Publications Describing Device

A new high performance field reversed configuration operating regime in the C-2 device


Description

The C-2 was a field reversed configuration device developed by TAE technologies. It was the first full scale device made by the company. A key accomplished goal of C-2 was to demonstrate a High Performance FRC (HPF), eg. improved confinement and stability compared to previous FRC efforts. Additionally the demonstration of heating and stability from Neutral Beam Injection was an important achievement of this device. In 2013, C-2 was upgraded to C-2U.

Affiliated Organizations
In Operation

2009 - 2013